TARGA Imager Enables High-Resolution Imaging of Neurodevelopmental Models

Sponsored content brought to you by

Lumencor logo

Neurodevelopment in schizophrenia poses major challenges for experimental study due at least in part to the brain’s genetic complexity, cellular diversity, and limitations in accessing living human tissue. To overcome such barriers, researchers often use complementary human stem cell–derived models: adherent cortical organoids and Neurogenin-2 (NGN2) induced neurons. Adherent cortical organoids form three-dimensional cultures containing diverse cortical neuron types, enabling analysis of network development and long-term maturation over months.1 In contrast, NGN2 neurons generate rapid, two-dimensional, homogeneous populations of excitatory neurons that display robust activity within weeks, making them well suited for scalable, functional assays, and high-throughput screening.2

With the added insight that stem cell models offer into the neural development of the schizophrenic brain, the quantification of patient-derived neurons’ collective function is a priority.3 At Columbia University’s Mortimer B. Zuckerman Mind Brain and Behavior Institute, researchers use NGN2 neurons, yielding reproducible populations of excitatory cortical neurons that scale reliably across experiments.

Calcium imaging provides a powerful functional readout in these NGN2 neuron networks. When a neuron fires an action potential, voltage-gated calcium channels open and intracellular calcium rises sharply.4 Fluorescence calcium indicators convert transient, ionic changes into fluorescence emission that can be quantitatively detected via light microscopy across thousands of cells simultaneously. Coupling calcium-sensitive reporters with high-speed optical microscopy enables noninvasive, population-level measurement of neural activity, synchrony, and network dynamics. Interpreting these rich image sequences requires sophisticated theoretical and numerical approaches.5

Building on the ability to measure neural activity with calcium imaging at scale, Lumencor’s TARGA Imager represents a transformative step in the development of optical imaging hardware for the study of neurodevelopmental conditions such as schizophrenia. It is well suited to workflows where NGN2-neuron cultures are studied across multiple conditions in parallel (Figure 1). In these contexts, TARGA delivers calcium fluorescence images over millimeter-scale fields of view within standard 96-well plates, entire well areas, while maintaining high-speed, faster-than video rate imaging with precision resolution.

Lumencor NGN2-neurons calcium imaging workflow
Figure 1. TARGA implementation for NGN2-neurons calcium imaging workflow

These capabilities allow researchers to observe chemical communications across large neuronal networks rather than isolated cells in real time. Images can be acquired at frequencies up to 100 Hz, enabling capture of fast calcium transients of collective neuronal dynamics. Rapid switching of multicolor excitation light supports multiplexed fluorescence dyes, linking functional activity with cellular structure and organization.

Overall, TARGA achieves high spatial, temporal, and spectral resolution simultaneously with precise, automated opto-mechanical architecture. These data are well matched to modern image analysis and AI algorithms, generating robust fluorescence traces from complex neuronal populations (Figure 2). In combination, these features make the TARGA Imager a revelatory neuroscience tool, uniquely enabling visualization of emergent collective behavior at millimeter scale with exceptional resolution. Such integrated performance accelerates discovery by bridging cellular mechanisms and systems-level phenotypes relevant to schizophrenia pathophysiology and therapeutic screening. By uniting scale, speed, and precision in a single optical platform, TARGA empowers researchers to probe experimental neuroscience and strengthens translational studies of complex psychiatric disease at population scale.

NGN2-neurons calcium imaging workflow
Figure 1. TARGA implementation for NGN2-neurons calcium imaging workflow

 

References

  1. Van der Kroeg et al. Human adherent cortical organoids in a multiwell format. eLife. 2024. 13:e98340.
  2. Shan et al. Fully defined NGN2 neuron protocol reveals diverse signatures of neuronal maturation. Cell Reports Methods. 2024. 4:100858.
  3. Rao et al. Aberrant pace of cortical neuron development in brain organoids from patients with 22q11.2 deletion syndrome‑associated schizophrenia. Nature Communications. 2025. 16:6986.
  4. Zhang et al. Fast and sensitive GCaMP calcium indicators for imaging neural populations. Nature. 2023. 615:884–891.
  5. Pasarkar et al. maskNMF: A denoise‑sparsen‑detect approach for extracting neural signals from dense imaging data. bioRxiv. 2023. 2023.09.14.557777.

 

Lumencor_June 2026 sponsored content QRCode

 

To learn more, visit: lumencor.com or contact our team at: info@lumencor.com.

The post TARGA Imager Enables High-Resolution Imaging of Neurodevelopmental Models appeared first on Inside Precision Medicine.